Free shipping on orders over $1000 Details >

Comtran VITALink 2 Hour Fire Rated Cable, 16-2 Shielded Fire Alarm Cable, FPLR Riser, LSZH

SKU CC35785
How will you purchase this wire?
5.730000 5.730000
truck FREE SHIPPING ON ORDERS OVER $1000
MIN: 1 FT. | MAX: 10000 FT. 1 10000 tooltip To order multiple lengths, simply enter the desired footage into the quantity fields. Each length will be delivered on its own spool.

Please Select Color(s)

Multiple colors can be selected

....
Quantity

Select your preferred quantity for each color below. Add additional colors and lengths as needed.

Comtran VITALink 2 Hour Fire Rated Cable, 16-2 Shielded Fire Alarm Cable, FPLR Riser, LSZH

Color Length (ft.) Price
Red

Length (ft.)

add Add a length
Grouped product items
Color Length (ft.)
Red Length 500 ft.
truck FREE SHIPPING ON ORDERS OVER $1000
Product Details

Learn everything you want to know about this product to make an informed purchase

Specifications
  • Wire Size

    30 AWG

  • # of Conductors

    2 Conductors

Data provided on this page is subject to change based on different manufacturers variances.
See Less
More information

Comtran VITALink 2 Hour Fire Rated Cable, 16-2 Fire Alarm Cable, FPLR Riser, Shielded

Color:

Red

Applications:
Emergency Voice/Alarm Communication Smoke and Fire Alarm Systems
Fireman’s Telephone and Area of Refuge Communication Systems
Visible Notification Appliances

Compliances:
NEC type FPLR-CI-LS, CMR-CI-LS, & CL3R-CI-LS for use in Electrical Circuit Integrity System FHIT 40A
c(UL) Listed CMR-LS
CEC and CSA listed FAS 105 to C22.2 No. 208-14
UL Certified to ANSI / UL 2196 2-Hour fire rating for use in FHIT system 40A. (See UL Fire Resistance Directory R27557)
CAN / ULC-S139 Certified with Hose Stream Test for use in FHIT7 system 40A
UL 1424 Listed FPLR-CI-LS for Power-Limited Fire Alarm Cables; 300V / 105°C
UL 13 Listed CL3R-CI-LS for Power-Limited Circuit Cables; 300V / 105°C
UL 444 Listed CMR-CI-LS for Communication Cable; 300V / 105°C
Fire certified for power-limited system use at 72V phase-to-phase utilization voltage
Sunlight Resistant
For use in wet locations
NYC Electrical Advisory Board approval # 54502, April 2017
California State Fire Marshal Approved

Conductor:
16 AWG Solid Copper specially engineered to minimize embrittlement due to fire exposure

Tape:
Flame Retardant Tape

Shield:
Copper/Polyester Tape applied over core

Drain Wire:
Stranded Bare Copper

Insulation:
Low Smoke, Zero Halogen Thermoset Fire-Roc™

Jacket:
Red Low Smoke, Zero Halogen Polyolefin (Sequential Footage Marker Provided Every Two Feet)

Core Assembly:
Color Coded Insulated Conductors of Red and Black

Specifications*:

Size: 16 AWG
Number of Conductors: 2
Nominal Diameter: 0.330 inches
Nominal Weight: 60 lbs per 1000ft 
Nominal Capacitance (pF/ft): 20

 

See Less