Free shipping on orders over $1000 Details >

6 AWG THHN/THWN-2 Copper Building Wire

SKU THN6

$

1.300000

1.300000

/ft
How will you purchase this wire?
1.300000 1.300000
truck FREE SHIPPING ON ORDERS OVER $1000
MIN: 1 FT. | MAX: 10000 FT. 1 10000 tooltip To order multiple lengths, simply enter the desired footage into the quantity fields. Each length will be delivered on its own spool.

Please Select Color(s)

Multiple colors can be selected

.... .... .... .... .... .... .... .... ....
Quantity

Select your preferred quantity for each color below. Add additional colors and lengths as needed.

6 AWG THHN/THWN-2 Copper Building Wire

Color Length (ft.) Price
Black

Length (ft.)

$1.30
add Add a length
Green

Length (ft.)

$1.30
add Add a length
White

Length (ft.)

$1.30
add Add a length
Red

Length (ft.)

$1.30
add Add a length
Blue

Length (ft.)

$1.30
add Add a length
Brown

Length (ft.)

$1.30
add Add a length
Orange

Length (ft.)

$1.30
add Add a length
Yellow

Length (ft.)

$1.30
add Add a length
Gray

Length (ft.)

$1.30
add Add a length
Grouped product items
Color Length (ft.)
Black Length 500 ft.
$650.00
Green Length 500 ft.
$650.00
White Length 500 ft.
$650.00
Red Length 500 ft.
$650.00
Blue Length 500 ft.
$650.00
Brown Length 500 ft.
$650.00
Orange Length 500 ft.
$650.00
Yellow Length 500 ft.
$650.00
Gray Length 500 ft.
$650.00
truck FREE SHIPPING ON ORDERS OVER $1000
Product Details

Learn everything you want to know about this product to make an informed purchase

Specifications
  • Cable Type

    THHN/THWN-2

  • Wire Size

    6 AWG

  • # of Conductors

    1 Conductor

  • Conductor Material

    Bare Copper

  • Stranded or Solid

    Stranded

  • Number of Strands

    19

  • O.D. (Inches)

    0.249

  • Ampacity

    75

  • Voltage

    600V

  • Temp. Rating

    90°C

  • Insulation Material

    PVC - Polyvinyl Chloride

  • Jacket Material

    Nylon

  • Direct Burial

    No

  • Location Use

    Wet, Dry

  • Indoor/Outdoor Use

    Indoor, Outdoor

  • Standards

    UL Listed, CSA Certified

  • Features

    Water Resistant, Oil & Gas Resistant, Heat Resistant

Data provided on this page is subject to change based on different manufacturers variances.
See Less
More information

#6 THHN/THWN-2 Wire

Cut to length - sold by the foot. Enter the desired footage in the QTY box.
Minimum 1' to maximum 2000'. Please call for longer put ups.

Applications:
6 AWG THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). 6 AWG THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations. Most common building wire used often on sub-panels, hot tubs & jacuzzis. 

Also Known As:
Copper wire, THWN-2 Wire, building wire, hook up wire, conduit wire, hot tub wire, lighting wire, nylon copper wire, construction cable, 6 gauge wire, etc.

Features:
Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.

Jacket:
A tough, polyamide, Nylon outer covering per UL-1063 and UL-83.

Standards:
Underwriters Laboratories Standards UL-83, UL-1063, UL-758
AWM Spec 1316, 1317, 1318, 1319, 1320, 1321
ASTM Stranding Class B3, B8, B787
Federal Specification A-A-59544
Canadian Standards Association C22.2 No. 75
NEMA WC70/ICEA S-95-658
Institute of Electrical and Electronics Engineers

Construction:
Conductors:
Solid, uncoated copper conductors per ASTM-B3
Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8
Insulation:
Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-8

6 AWG THHN/THWN-2 Specifications*:

 
Size: 6 AWG
Number of Strands: 19
Cross Section Area: 13.3 mm2
PVC Insulation Thickness (Conductor): 0.760 mm / 0.030 inches
Nylon Jacket Thickness: 0.130 mm / 0.005 inches
Outside Diameter: 6.30 mm / 0.248 inches
Weight: 0.109 lbs per ft
Allowable Ampacity: 55 Amps at 60ºC / 65 Amps at 75ºC / 75 Amps at 90ºC

*Data provided on this page is subject to change based on different manufacturers variances.

See Less