Free shipping on orders over $1000 Details >

4/0 MV-105, 5kV/8kV, EPR/PVC Power Cable w/ Copper Tape Shield

4/0 MV-105, 5kV/8kV, EPR/PVC Power Cable w/ Copper Tape Shield
SKU MV1054s0

$

21.970000

21.970000

/ft
How will you purchase this wire?
21.970000 21.970000
truck FREE SHIPPING ON ORDERS OVER $1000
MIN: 1 FT. | MAX: 10000 FT. 1 10000 tooltip To order multiple lengths, simply enter the desired footage into the quantity fields. Each length will be delivered on its own spool.

Please Select Color(s)

Multiple colors can be selected

....
Quantity

Select your preferred quantity for each color below. Add additional colors and lengths as needed.

4/0 MV-105, 5kV/8kV, EPR/PVC Power Cable w/ Copper Tape Shield

Color Length (ft.) Price
N/A

Length (ft.)

$21.97
add Add a length
Grouped product items
Color Length (ft.)
N/A Length 500 ft.
$10,985.00
truck FREE SHIPPING ON ORDERS OVER $1000
Product Details

Learn everything you want to know about this product to make an informed purchase

Specifications
  • Wire Size

    4/0 AWG

  • O.D. (Inches)

    1.05

  • Ampacity

    280

Data provided on this page is subject to change based on different manufacturers variances.
See Less
More information

Cut to length - sold by the foot. Enter the desired footage in the QTY box.
Minimum 100' to maximum 1000'. Please call for longer put ups.

Applications:
For use in power circuits up to 8 kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations.

Jacket:
Black Polyvinylchloride (PVC) Jacket, sunlight resistant

Standards:
Listed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1/0 and larger marked "for CT use" and pass UL 1685 70,000 Btu/hr flame test

Conductors:
Class B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semi-conducting thermoset

Insulation:
Ethylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)

Insulation Shield:
Extruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape

Ampacity:  
Based on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C

Temperature:  
105°C

Voltage:  
5 kV 133% and 8 kV 100%

Specifications*:

Size: 4/0
Number of Strands: 19
Insulation Thickness: 0.115 inches
Jacket Thickness: 0.080 inches
Outside Diameter: 1.05 inches
Weight: 1.085 lbs per ft
Amps per Conductor: 280 amps

*Data provided on this page is subject to change based on different manufacturers variances.

See Less