Free shipping on orders over $1000 Details >

10 AWG THHN Solid Building Wire, 100ft

SKU THN10-SOL-100

$

33.840000

33.840000

/ft
How will you purchase this wire?
33.840000 33.840000
truck FREE SHIPPING ON ORDERS OVER $1000

Please Select Color(s)

Multiple colors can be selected

.... .... .... .... .... .... .... .... ....

Multiple lengths can be selected

Each
Quantity

Select your preferred quantity for each color below. Add additional colors and lengths as needed.

10 AWG THHN Solid Building Wire, 100ft

Grouped product items
Color Length (ft.)
Black Length Each ft.
$33.84
White Length Each ft.
$33.84
Red Length Each ft.
$33.84
Green Length Each ft.
$33.84
Yellow Length Each ft.
$33.84
Blue Length Each ft.
$33.84
Brown Length Each ft.
$33.84
Orange Length Each ft.
$33.84
Gray Length Each ft.
$33.84
truck FREE SHIPPING ON ORDERS OVER $1000
Product Details

Learn everything you want to know about this product to make an informed purchase

Specifications
  • Cable Type

    THHN/THWN-2

  • Wire Size

    30 AWG

  • # of Conductors

    1 Conductor

  • Conductor Material

    Bare Copper

  • Stranded or Solid

    Solid

  • Voltage

    600V

  • Temp. Rating

    90°C

  • Insulation Material

    PVC - Polyvinyl Chloride

  • Jacket Material

    Nylon

  • Direct Burial

    No

  • Location Use

    Wet, Dry

  • Indoor/Outdoor Use

    Indoor, Outdoor

  • Standards

    UL Listed, CSA Certified

  • Features

    Water Resistant, Oil & Gas Resistant, Heat Resistant

Data provided on this page is subject to change based on different manufacturers variances.
See Less
More information

THHN Solid Building Wire. 100ft Coil

Applications:
Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.

Also Known As:
10 Gauge Copper Wire, 10 Gauge THWN, #10 THHN, hook up wire, conduit wire, bathtub wire, lighting wire, nylon copper wire, construction cable, etc...

Features:
Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.

Jacket:
A tough, polyamide, Nylon outer covering per UL-1063 and UL-83.

Standards:
Underwriters Laboratories Standards UL-83, UL-1063, UL-758
AWM Spec 1316, 1317, 1318, 1319, 1320, 1321
ASTM Stranding Class B3, B8, B787
Federal Specification A-A-59544
Canadian Standards Association C22.2 No. 75
NEMA WC70/ICEA S-95-658
Institute of Electrical and Electronics Engineers

Construction:
Conductors:
Solid, uncoated copper conductors per ASTM-B3
Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8
Insulation:
Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-8

Specifications*:

Size: 10 AWG
Stranding: Solid
Cross Section Area (mm2): 5.26
PVC Insulation Thickness (Conductor): 0.510 mm / 0.020 inches
Nylon Jacket Thickness: 0.100 mm / 0.004 inches
Outside Diameter: 3.78 mm / 0.149 inches
Allowable Ampacity: 30 Amps at 60ºC / 30 Amps at 75ºC / 30 Amps at 90ºC

*Data provided on this page is subject to change based on different manufacturers variances.