Free shipping on orders over $1000 Details >

10/3C Type MC-HL Aluminum Armored Cable w/ PVC Jacket

SKU MCHL103C

$

6.970000

6.970000

/ft
How will you purchase this wire?
6.970000 6.970000
truck FREE SHIPPING ON ORDERS OVER $1000
MIN: 1 FT. | MAX: 10000 FT. 1 10000 tooltip To order multiple lengths, simply enter the desired footage into the quantity fields. Each length will be delivered on its own spool.

Please Select Color(s)

Multiple colors can be selected

....
Quantity

Select your preferred quantity for each color below. Add additional colors and lengths as needed.

10/3C Type MC-HL Aluminum Armored Cable w/ PVC Jacket

Color Length (ft.) Price
Black

Length (ft.)

$6.97
add Add a length
Grouped product items
Color Length (ft.)
Black Length 500 ft.
$3,485.00
truck FREE SHIPPING ON ORDERS OVER $1000
Product Details

Learn everything you want to know about this product to make an informed purchase

Specifications
  • Wire Size

    10 AWG

  • O.D. (Inches)

    0.72

  • Ampacity

    40

Data provided on this page is subject to change based on different manufacturers variances.
See Less
More information

10/3C Type MC-HL Aluminum Armored Cable w/ PVC Jacket - 3#14 Ground Wires

Applications:
Control and lighting circuits in manufacturing and processing plants, feeders in industrial and commercial distribution systems. May be directly buried or installed in cable tray or raceway.

Conductor:
Class B stranded, bare, annealed copper per ASTM B-3 and B-8 

Insulation:
Cross-Linked Polyethylene (XLP) meeting the requirements of ICEA S-95-658 (NEMA WC70) and Type XHHW requirements of UL, color coding is Method 1, Table E-2 

Assembly:
The insulated conductors and a single, uninsulated UL ground wire(s) are cabled with fillers to make round

Armor:
An impervious, corrugated continuous seam-welded aluminum alloy sheath in accordance with UL 1569. Armor is pressure-tested and meets the grounding requirements of NEC Article 250

Overall Jacket:
Black, sunlight-resistant Polyvinyl Chloride (PVC)

Ampacity:
Based on not more than three conductors in raceway or cable or earth and an ambient temperature of 30°C per NEC table 310.16. All multiconductor values have been derated per 2008 NEC Table 310.15(B)(2)(a) – TEMPERATURE: 90

Standards:
Cables are UL listed for cable tray use and meet the IEEE 1202 (70,000 Btu/hr) flame test. Individual conductors and completed cables are tested in accordance with UL 2225 requirements for Type MC-HL cables 

Specifications*:

Size: 10 AWG
Conductor: 3 Conductor
Ground Wires: 3 #14AWG
Outside Diameter: 0.720 inches
Ampere Rating: 40

 

*Data provided on this page is subject to change based on different manufacturers variances.

See Less