Copper USE-2 / RHH / RHW-2 Wire (XLPE Insulation)

Wire & Cable Your Way offers a wide selection of XLP/USE-2/RHH/RHW-2 Building Wire products cut by the foot at low prices & fast shipping. These cables featue an XLPE jacket. USE-2 or RHW-2 or RHH 90°C - 600 Volt Stranded Building Wire is suitable for use in general purpose wiring applications and may be installed in raceway, conduit, direct burial and aerial installations where a cable having superior flame retardance is required. USE-2 or RHW-2 or RHH Building Wire is commonly used as solar wire for various applications.

For more details Click here.

Copper USE-2 / RHH / RHW-2 Wire (XLPE Insulation)

Wire & Cable Your Way offers a wide selection of XLP/USE-2/RHH/RHW-2 Building Wire products cut by the foot at low prices & fast shipping. These cables featue an XLPE jacket. USE-2 or RHW-2 or RHH 90°C - 600 Volt Stranded Building Wire is suitable for use in general purpose wiring applications and may be installed in raceway, conduit, direct burial and aerial installations where a cable having superior flame retardance is required. USE-2 or RHW-2 or RHH Building Wire is commonly used as solar wire for various applications.

For more details Click here.

Filter Results
Solid Copper XLP/USE-2/RHW-2
  1. Product Name
    Price
    Quick View
Stranded Copper XLP/USE-2/RHW-2
  1. Product Name
    Price
    Quick View
  2. $2.62 /ft.

    In Stock

Copper USE-2/RHH/RHW-2 with XLPE Insulation

USE-2 Cable Properties

Underground
Service
Entrance Cable

Rated for Direct Burial
600 V Stranded Building Wire, UL recognized cross-linked Polyethylene Insulation XLPE

Application:
USE-2 cables are primarily used for power distribution, in raceways in accordance with National Electrical Code, except that the cable is not rated for use in cable tray. USE-2 is approved for direct burial and for service entrance below ground. USE-2 cables may be used in wet or dry locations, with ambient temperatures not exceeding 90°C. Voltage rating for USE-2 cable is 600V

Applicable Standards:
USE-2 meets or exceeds the following standards
UL 44
Requirements of the National Electrical Code
ASTM standards B 800, B 801
Sunlight resistant 

Description:
Single copper conductor, stranded, insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation. Temperature rating 90° C in wet and dry applications.available.

Insulation:
USE-2 has abrasion, heat and moisture resistant cross-linked polyethylene insulation XLPE