12 AWG 4 Conductor Unshielded EPR/CPE Tray Cable

Min: 30 ft., Max: 10000 ft. To order multiple lengths, simply enter the desired footage into the quantity fields. Each length will be delivered on its own spool.
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Add a length

 Free Shipping on all orders over $1000

#12-4C EPR/CPE Tray Cable

SKU
EPR124C-FT

Product Details

Learn everything you want to know about this product to make an informed purchase

12 AWG 4 Conductor Unshielded EPR/CPE Tray Cable & Control Cable, 600V
Sunlight Resistant & Rated for Direct Burial. 

Cut to length - sold by the foot. Enter the desired footage in the QTY box.
Minimum 50' to maximum 1000'. Please call for longer put ups.

Color:
Black

Applications:
In free air, raceways or direct burial.
In wet or dry locations.
Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC.
Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors.

Features:
Rated at 90˚C wet or dry.
Ripcord applied to all cables with jacket thickness of 60 mils or less.
Excellent physical, thermal and electrical properties.
Sunlight- and weather-resistant.
Excellent moisture resistance.
Excellent resistance to compression cuts and heat deformation
Low coefficient of friction for easy pulling
Excellent flame resistance—burns to ash; does not exhibit thermoplastic drip
Excellent low temperature cold bend characteristics
Meets cold bend test at -40˚C
Meets the crush and impact requirements of Type MC cable for 3 or more conductors

Compliances:
Meets UL 1277 requirements for Type TC cables having VW-1, XHHW-2 conductors.
Cables rated for direct burial and meet the IEEE 1202, IEEE 383, and UL 1685.
70,000 Btu/hr flame tests as well as the ICEA T-29-520, 210,000 Btu/hr flame test

Conductor:
Stranded tinned copper per ASTM B33. Class B stranding per ASTM B8

Insulation:
Flame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)

Jacket:
Sunlight resistant, flame-retardant thermoplastic Chlorinated Polyethylene (CPE)

Color Code:
Black, Red, Blue, Orange

Specifications*:

Size: 12 AWG
Number of Conductors: 4
Conductor Strand: 7/.0305
Minimum AVG Insulation Thickness: 0.76 mm / 0.030 inches
Minimum AVG Jacket Thickness: 1.14 mm / 0.045 inches
Outside Diameter: 0.475 inches
Weight: 0.157 lbs per ft
Voltage: 600V

*Data provided on this page is subject to change based on different manufacturers variances.

More Information
Wire Size12 AWG
# of Conductors4 Conductors
O.D. (Inches)0.475