#8-3C + #18-9C w/ #10 Ground Type TC/TC-ER-JP Generator Cable

SKU VNT83189CG

$

4.420000

4.420000

/ft
How will you purchase this wire?
4.420000 4.420000
truck FREE SHIPPING ON ORDERS OVER $1000
MIN: 1 FT. | MAX: 10000 FT. 1 10000 tooltip To order multiple lengths, simply enter the desired footage into the quantity fields. Each length will be delivered on its own spool.

Please Select Color(s)

Multiple colors can be selected

....
Quantity

Select your preferred quantity for each color below. Add additional colors and lengths as needed.

#8-3C + #18-9C w/ #10 Ground Type TC/TC-ER-JP Generator Cable

Color Length (ft.) Price
Black

Length (ft.)

$4.42
add Add a length
truck FREE SHIPPING ON ORDERS OVER $1000
Product Details

Learn everything you want to know about this product to make an informed purchase

Specifications
  • Wire Size

    8 AWG

  • # of Conductors

    3 Conductors w/ Ground

  • O.D. (Inches)

    0.64

  • Ampacity

    50

  • Voltage

    600V

  • Temp. Rating

    90°C

  • Location Use

    Wet, Dry

  • Indoor/Outdoor Use

    Indoor, Outdoor

Data provided on this page is subject to change based on different manufacturers variances.
See Less
More information

#8-3C + #18-9C w/ #10 Ground Type TC/TC-ER-JP Generator Composite Cable (50 amps, 7kW-11kW)

Cut to length - sold by the foot. Enter the desired footage in the QTY box.
Minimum 50' to maximum 1000'. Please call for longer put ups.

Color:
Black

Applications: 

Multi-conductor all in one cable for connecting a generator to a transfer switch. JP (Joist Pull) rated per the 2017 NEC 336.10(9). Black jacket and color coded inner conductors. 

Specifications:

Size: 4 AWG (3 Conductors), 18 AWG (9 Conductors) Ground Wire Size: 8 AWG Allowable Ampacity: 85 Amps

 

Standards

UL Listed as TC-ER-JP per UL Standard 1277 Rated 75C wet or dry to meet UL 83 for THHN/THWN Meets cold bend test at -40°C ICEA S-73-532 Meets UL 1581 & 1202 (FT-4) 70,000 BTU/HR & ICEA T-29-520 210,000 BTU/HR requirements REACH compliant per Regulation (EC) No 1907/2006 (197) Updated January 15, 2019 Cable is suitable for use in Class I Division 2 hazardous locations Element 1 & 2 conductors pass UL VW-1 flame test, rated THWN/VW-1 ASTM B3, B174, B801

 

***THIS MATERIAL IN NON-RETURNABLE***

All values are nominal and subject to correction.
*Ampacity according to NEC 310.15(B)(16) @30°C THWN 75°C insulated wires.
**Installations shall follow NEC, applicable correcting factors shall be considered when conditions vary.