Free shipping on orders over $1000 Details >

3/3 MC Cable w/ Ground, Stranded Copper Conductors

SKU MC33C

$

9.400000

9.400000

/ft
How will you purchase this wire?
9.400000 9.400000
truck FREE SHIPPING ON ORDERS OVER $1000

Please Select Color(s)

Multiple colors can be selected

....

Multiple lengths can be selected

50 100 125 250 500 1000
Quantity

Select your preferred quantity for each color below. Add additional colors and lengths as needed.

3/3 MC Cable w/ Ground, Stranded Copper Conductors

Grouped product items
Color Length (ft.)
N/A Length 50 ft.
$470.00
N/A Length 100 ft.
$940.00
N/A Length 125 ft.
$1,175.00
N/A Length 250 ft.
$2,350.00
N/A Length 500 ft.
$4,700.00
N/A Length 1000 ft.
$9,400.00
truck FREE SHIPPING ON ORDERS OVER $1000
Product Details

Learn everything you want to know about this product to make an informed purchase

Specifications
  • Cable Type

    MC

  • Wire Size

    3 AWG

  • # of Conductors

    3 Conductors w/ 3 Grounds

  • Conductor Material

    Bare Copper

  • Stranded or Solid

    Stranded

  • O.D. (Inches)

    1.009

Data provided on this page is subject to change based on different manufacturers variances.
See Less
More information

3-3C Metal Clad (MC) Cable with #6 Ground, Aluminum Armored, Stranded Copper Conductors

Applications:
Branch, feeder or service power distribution in commercial, industrial, institutional and multi-residential buildings. Lighting, power, control and signal circuits. • Fished or embedded in plaster, concealed or exposed installations. Environmental air handling spaces per NEC 300.22 (C).
Places of assembly and theaters.
Under raised floors for technology equipment conductors and cables.
Installation in cable tray and approved raceways.
Class I Div.2, Class II Div.2, Class III Div. 1 Hazardous Locations.
Voltage rating for all applications is not to exceed 600 Volts.

Construction:
Type MC cables are constructed of soft-drawn bare copper with lead-free THHN/THWN-2 rated at 90˚C dry and available in sizes #14 AWG through and including #2 AWG, and including the green insulated ground conductor. The conductors are cabled, wrapped completely in a Mylar binder tape with an aluminum tape interlocked sheath applied over the entire assembly

Standards:
ASTM B-3, B-8 and B-787
UL 83, UL 1569, UL 1581 and UL 2556
NEC 2014 : 300.22 (C), 310.10, 330,392, 518, 520, 530, 645
NFPA 70
Federal Specification A-A59544
IEEE 1202 (70,000 BTU/hr) Vertical Flame Test/FT4
CT Rated for 600 Volts if installed per the NEC directives
Rated for 1 and 2 hour Through Penetration
RoHS Compliant
ARRA 2009 Buy American Compliant

Specifications*:

Conductors: 3 + 1 Ground (4 total conductors)
Size: 3 AWG 
Ground Size: 6 AWG
Outside Diameter: 1.009 inches
Weight: 1.175 per ft. 

*Data provided on this page is subject to change based on different manufacturers variances.