Free shipping on orders over $1000 View Details
$20.75 /ft.

In Stock

#3/0-3C THHN-PVC Tray Cable with Ground

Min: 10 ft., Max: 1000 ft. To order multiple lengths, simply enter the desired footage into the quantity fields. Each length will be delivered on its own spool.
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Add a length

 Free Shipping on all orders over $1000

#3/0-3C THHN-PVC Tray Cable with Ground

SKU
VNT3s03CG-FT

Product Details

Learn everything you want to know about this product to make an informed purchase

PVC/Nylon/PVC, Control, Unshielded, 600V, UL Type TC-ER

Cut to length - sold by the foot. Enter the desired footage in the QTY box.
Minimum 1' to maximum 2000'. Please call for longer put ups.

Color:
Black

Applications:
In free air, raceways or direct burial. In wet or dry locations. Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Permitted for Exposed Run (ER) use in accordance with NEC.

Also Known As:
raceway cable, underground cable, multi-conductor THHN cable, lighting cable, control cable, signal and communication circuit cable, etc.

Features:
Rated at 90°C dry, 75°C wet. Ripcord applied to all cables with jacket thickness of 60 mils or less. Provides outstanding sunlight, cold bend and cold impact resistance. Offers the smallest cable O.D. available for suitable applications. Provides long service life. Provides good oil and chemical resistance. Meets cold bend test at -25°C. Meets the crush and impact requirements of Type MC cable.

Compliances:
Industry Compliances:
- UL 66 NEC Type TFN conductors
- UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179
- UL 1581
- ICEA S-95-658
Flame Test Compliances:
- UL 1277
- IEEE 383
- IEEE 1202
- CSA FT4
Other Compliances:
- EPA 40 CFR, Part 261 for leachable lead content per TCLP
- OSHA Acceptable
- RoHS Compliant

Conductor:
Fully annealed stranded bare copper to ASTM B3
Class B stranding per ASTM B8

Insulation:
Flame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)
Color-coded per ICEA Method 4

Ground:
Uninsulated bare annealed copper per ASTM B3
Class B stranding per ASTM B8

Jacket:
Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)

Options:
Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)

Specifications*:

Size: 3/0 AWG
Number of Conductors: 3
Conductor Strand: 19/.0837
Ground Wire Size: 6 AWG
Minimum AVG Insulation Thickness: 1.50 mm / 0.059 inches
Minimum AVG Jacket Thickness: 2.03 mm / 0.080 inches
Outside Diameter: 36.75 mm / 1.45 inches
Net Weight: 2.20 lbs per ft
Allowable Ampacity: 225 Amps

Bend Radius: 5 x overall diameter installed (up to 2.0") / 6 overall diameter installed (over 2.0")
8 x overall diameter during installation pull-in.

*Data provided on this page is subject to change based on different manufacturers variances.

More Information
Wire Size3/0 AWG
# of Conductors3 Conductors w/ Ground
O.D. (Inches)1.45
Ampacity225
Temp. Rating90°C
Location UseWet, Dry
Indoor/Outdoor UseIndoor, Outdoor