$20 Order Minimum. Questions? Call: 855-880-8010
 

2-3C w/ Ground Shielded VFD Cable

$16.53
SKU: VFD2-3C
Minimum Quantity: 20
Maximum Quantity: 2000
Availability: IN STOCK
Quantity: Information
 
 
 
 
Eligible for FREE Shipping
  • Description

XLPO Insulation, PVC Jacket, 600/1000V UL Type TC-ER, 90°C

Cut to length - sold by the foot. Enter the desired footage in the QTY box.
Minimum 20' to maximum 1000'. Please call for longer put ups.

Applications:
A flexible, shielded power cable specifically engineered for use in variable frequency AC motor drive (VFD) applications.

Conductor:
Stranded copper circuit conductors

Insulation:
Crossed-linked polyolefin (XLPO), flexible and low dielectric

Jacket:
Black sunlight resistant polyvinyl chloride (PVC)

Color Code:
Black with number surface printed in contrasting ink

Overall Shield:
Braid of tinned copper wires and a poly aluminum tape, helically applied and lapped

Grounding Conductor:
One full-size tinned copper conductor with solid green cross-linked polyolefin (XLPO) insulation

Drain Wire:
Tinned copper wires

Compliances:
-UL Listed as Type TC-ER 600V
-UL Listed as 1kV Flexible Motor Supply Cable (up to 4/0 AWG)
- 90°C Temperature Rating
- FT-4 and IEEE 1202 Flame Ratings
- Sunlight Resistant
- Oil Resistant (Oil Res I)
- Direct Burial        
- Meets crush and impact requirements for Type MC cable
- Permitted for Exposed Run (“ER”) use in accordance with the NEC
- Permitted for use in Class 1, Division 2 and Zone 2 industrial hazardous locations per the NEC

Specifications*:

Size: 2 AWG
Number of Conductors: 3
Conductor Strand: 133
Insulation Thickness: 0.045 inches
Ground Wire: 2 AWG
Ground Wire Stranding: 133
Drain Wire Size:  8 AWG (4x)
Drain Wire Stranding: 37
Jacket Thickness: 0.080 inches
Outside Diameter: 1.252 inches
Weight: 1.614 lbs per ft

Other: 
• Specially engineered cable design produces a longer cable life in VFD applications
• Overall shield provides 100% coverage containing VFD EMI emissions
• High strand count design is much more flexible, easier to install and more resistant to vibration than Type MC cable • Specially formulated insulation material with a lower dielectric constant (standard XLPE and EPR insulation materials have higher dielectric constants) withstands reflected voltages, allowing for longer output cable distances and minimizes the effect of high frequency noise induced into the plant ground system
• Gas and vapor tight - impervious to water and air
• Reduced installation time and cost compared to Type MC
• Glands for this product cost up to 50% less than those for Type MC
• Bend Radius is 8 x O.D.

 

*Data provided on this page is subject to change based on different manufacturers variances.