16 AWG 6 Pair Type TC-ER, Tray Cable, Individual/Overall Shield, 600V

Min: 30 ft., Max: 10000 ft. To order multiple lengths, simply enter the desired footage into the quantity fields. Each length will be delivered on its own spool.
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Add a length

 Free Shipping on all orders over $1000

16 AWG 6 Pair Type TC-ER, Tray Cable, Individual/Overall Shield, 600V

SKU
VNT166SPOS-FT

Product Details

Learn everything you want to know about this product to make an informed purchase

16 AWG 6 Pair Type TC-ER, Tray Cable, Individual/Overall Shield, 600V
Sunlight & Oil Resistant, Approved for Direct Burial

Cut to length - sold by the foot. Enter the desired footage in the QTY box.

Minimum 50' to maximum 1000'. Please call for longer put ups.

Color:
Black

Applications:
For use indoors or outdoors and for installation in trays, troughs, channels, ducts and direct burial. Designed for telemetering, signals, relays and communication.  Permitted use in Class 1, Division 2 industrial hazardous locations per NEC.

Features:
Sunlight & Oil Resistant
Rated for Direct Burial
90°C applications

Standards:
- Refer to NEC (NFPA 70) article 336 for installation guidelines
- Cable is suitable for use in Class I Division II hazardous locations
- UL listed as Type TC-ER per UL Standard 1277 for tray cables
- UL approved for Direct Burial, Sunlight and Oil I Resistant applications
- Cable meets UL 1581 & 1202 (FT-4) 70,000 BTU/HR & ICEA T-29-520 210,000 BTU/HR requirements 6.6. Meets ICEA S-73-532, where applicable
- All materials used in the manufacture of this cable are RoHS compliant
- Made in the USA
 

Conductor:
16 AWG bare copper, Class B stranded per ASTM B-8

Insulation:
Polyvinyl Chloride (PVC) and nylon, pairs are color coded black and white and numbered, triads are black, white, red and numbered

Jacket:
Sunlight-resistant Polyvinyl Chloride (PVC)

Shielding:
Tinned copper, where applicable, individual drain wires are used, also of seven-strand, tinned copper construction

Specifications*:

Size: 16 AWG
Number of Pairs: 6
Minimum AVG Insulation Thickness: 0.51 mm / 0.020 inches
Overall Jacket Thickness: 0.060 inches
Outside Diameter: 0.660 inches
Net Weight: 0.282 lbs per ft

 

 

*Data provided on this page is subject to change based on different manufacturers variances.

More Information
Wire Size16 AWG
# of Conductors12 Conductors
# of Pairs6 Pair
O.D. (Inches)0.66