16 AWG 3C Type P Power Cable, 600/1000V. Cut to length - sold by the Foot.

Min: 50 ft., Max: 10000 ft. To order multiple lengths, simply enter the desired footage into the quantity fields. Each length will be delivered on its own spool.
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Add a length

 Free Shipping on all orders over $1000

16 AWG 3C Type P Power Cable, 600/1000V

SKU
TPC163C-FT

Product Details

Learn everything you want to know about this product to make an informed purchase

16 AWG 3C Type P Power Cable, 600/1000V

Cut to length - sold by the foot. Enter the desired footage in the QTY box.
Minimum 10' to maximum 1000'. Please call for longer put ups.

Applications:
Designed and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.

Conductor:
Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11.

Insulation:
Flame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA C22.2 No. 245. Color Code: Black-White-Red. (Black-White-Green on request) Sizes 1/0 and Larger: Black with Phase ID Imprint.

Jacket:
Black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA C22.2 No. 245 and IEEE 1580.

Compliances:
• American Bureau of Shipping (ABS)
• Transport Canada
• Det Norske Veritas (DNV)
• Lloyd's Register of Shipping (LRS)
• NVE 95/1696, FAL
• UL listed as Marine Shipboard Cable
• United States Coast Guard
• CSA listed as Marine Shipboard Cable 

Features:
• High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.
• Lower dielectric constant and higher insulation resistance reduces electrical losses.
• Excellent resistance to moisture produces stable electrical properties throughout the life of the cable.
• In fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.
• Dual certified IEEE 1580 Type P and UL 1309/CSA C22.2 No. 245 Type X110.
• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C
• Severe cold durability: exceeds CSA cold bend/cold impact (-40/-35° C)
• Flame retardant: IEC 60332-3 Category A and IEEE 1202

Specifications*:

Size: 16 AWG
Number of Conductors: 3
Nominal Diameter: 0.369 inches 
Inductive Reactance (Ohms/1000 ft.): 0.039
Voltage Drop at 110°C (Volts/Amp/1000ft.): 8.511
DC Resistance at 25°C ((Ohms/1000 ft.): 4.610
AC Resistance at 110°C (Ohms/1000 ft.): 06.121
Current AMPS: Free Air 110°C = 17, 100°C = 16, 95°C = 16
Net Weight: 0.065 lbs per ft

*Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance.

More Information
StockedYes
Wire Size16 AWG
# of Conductors3 Conductors
Conductor MaterialTinned Copper
O.D. (Inches)0.369
Ampacity 17
Jacket ColorBlack