Free shipping on orders over $1000 Details >

14 AWG THHN/THWN-2 Solid Building Wire - sold by the spool

SKU THN14SOL

$

0.170000

0.170000

/ft
How will you purchase this wire?
0.170000 0.170000
truck FREE SHIPPING ON ORDERS OVER $1000

Please Select Color(s)

Multiple colors can be selected

.... .... .... .... .... .... .... .... .... ....

Multiple lengths can be selected

500 1000 2500
Quantity

Select your preferred quantity for each color below. Add additional colors and lengths as needed.

14 AWG THHN/THWN-2 Solid Building Wire - sold by the spool

Grouped product items
Color Length (ft.)
Black Length 500 ft.
$85.00
White Length 500 ft.
$85.00
Red Length 500 ft.
$85.00
Green Length 500 ft.
$85.00
Yellow Length 500 ft.
$85.00
Blue Length 500 ft.
$85.00
Brown Length 500 ft.
$85.00
Orange Length 500 ft.
$85.00
Gray Length 500 ft.
$85.00
Black Length 1000 ft.
$170.00
White Length 1000 ft.
$170.00
Red Length 1000 ft.
$170.00
Green Length 1000 ft.
$170.00
Yellow Length 1000 ft.
$170.00
Blue Length 1000 ft.
$170.00
Brown Length 1000 ft.
$170.00
Orange Length 1000 ft.
$170.00
Gray Length 1000 ft.
$170.00
Yellow w/ Green Stripe Length 1000 ft.
$170.00
Black Length 2500 ft.
$425.00
White Length 2500 ft.
$425.00
Red Length 2500 ft.
$425.00
Green Length 2500 ft.
$425.00
Yellow Length 2500 ft.
$425.00
Blue Length 2500 ft.
$425.00
Brown Length 2500 ft.
$425.00
Orange Length 2500 ft.
$425.00
Gray Length 2500 ft.
$425.00
Yellow w/ Green Stripe Length 2500 ft.
$425.00
truck FREE SHIPPING ON ORDERS OVER $1000
Product Details

Learn everything you want to know about this product to make an informed purchase

Specifications
  • Jacket Color

    White;Black

  • Cable Type

    THHN/THWN-2

  • Wire Size

    14 AWG

  • # of Conductors

    1 Conductor

  • Conductor Material

    Bare Copper

  • Stranded or Solid

    Solid

  • O.D. (Inches)

    0.101

  • Ampacity

    15

  • Voltage

    600V

  • Temp. Rating

    90°C

  • Insulation Material

    PVC - Polyvinyl Chloride

  • Jacket Material

    Nylon

  • Direct Burial

    No

  • Location Use

    Wet, Dry

  • Indoor/Outdoor Use

    Indoor, Outdoor

  • Standards

    UL Listed, CSA Certified

  • Features

    Water Resistant, Oil & Gas Resistant, Heat Resistant

Data provided on this page is subject to change based on different manufacturers variances.
See Less
More information

10 Gauge THHN Solid Copper Building Wire. Sold by the spool.

Applications:
Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations

Also Known As:
Copper wire, THWN, building wire, hook up wire, conduit wire, bathtub wire, lighting wire, nylon copper wire, construction cable, etc...

Features:
Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.

Jacket:
A tough, polyamide, Nylon outer covering per UL-1063 and UL-83.

Standards:
Underwriters Laboratories Standards UL-83, UL-1063, UL-758
AWM Spec 1316, 1317, 1318, 1319, 1320, 1321
ASTM Stranding Class B3, B8, B787
Federal Specification A-A-59544
Canadian Standards Association C22.2 No. 75
NEMA WC70/ICEA S-95-658
Institute of Electrical and Electronics Engineers

Construction:
Conductors:
Solid, uncoated copper conductors per ASTM-B3
Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8
Insulation:
Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-8

Specifications*:

Size: 14 AWG
Stranding: Solid
Cross Section Area (mm2): 2.08
PVC Insulation Thickness (Conductor): 0.380 mm / 0.015 inches
Nylon Jacket Thickness: 0.100 mm / 0.004 inches
Outside Diameter: 2.57 mm / 0.101 inches
Allowable Ampacity: 15 Amps at 60ºC / 15 Amps at 75ºC / 15 Amps at 90ºC

*Data provided on this page is subject to change based on different manufacturers variances.

See Less