Applications:
Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.
Also Known As:
10 Gauge Copper Wire, #10 AWG THWN, building wire, 10 gauge hook up wire, conduit wire, bathtub wire, lighting wire, nylon copper wire, construction cable, 10 gauge wire, #10 awg wire, 500' spool of 10 AWG Wire
Features:
Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.
Jacket:
A tough, polyamide, Nylon outer covering per UL-1063 and UL-83.
Standards:
Underwriters Laboratories Standards UL-83, UL-1063, UL-758
AWM Spec 1316, 1317, 1318, 1319, 1320, 1321
ASTM Stranding Class B3, B8, B787
Federal Specification A-A-59544
Canadian Standards Association C22.2 No. 75
NEMA WC70/ICEA S-95-658
Institute of Electrical and Electronics Engineers
Construction:
Conductors:
Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8
Insulation:
Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-8
Specifications*:
Size: 10 AWG
Number of Strands: 19
Cross Section Area (mm2): 5.26
PVC Insulation Thickness (Conductor): 0.510 mm / 0.020 inches
Nylon Jacket Thickness: 0.100 mm / 0.004 inches
Outside Diameter: 4.07 mm / 0.160 inches
10 AWG THHN Ampacity: 30 Amps at 60ºC / 30 Amps at 75ºC / 30 Amps at 90ºC
*Data provided on this page is subject to change based on different manufacturers variances.
Stocked | Yes |
---|---|
Cable Type | THHN/THWN-2 |
Wire Size | 10 AWG |
# of Conductors | 1 Conductor |
Conductor Material | Bare Copper |
Stranded or Solid | Stranded |
Number of Strands | 19 |
O.D. (Inches) | 0.16 |
Ampacity | 30 |
Voltage | 600V |
Temp. Rating | 90°C |
Insulation Material | PVC - Polyvinyl Chloride |
Jacket Material | Nylon |
Location Use | Wet, Dry |
Indoor/Outdoor Use | Indoor, Outdoor |
Standards | UL Listed, CSA Certified |