#10-12C XLP/PVC Tray Cable

SKU
XLP1012C-FT

Product Details

Learn everything you want to know about this product to make an informed purchase

Industrial Tray Cable. 600 Volts, 90°C Wet or Dry

Cut to length - sold by the foot. Enter the desired footage in the QTY box.
Minimum 20' to maximum 1000'. Please call for longer put ups.

Color:
Black

Applications:
XLP/PVC Control Cable is intended for use where flame retardance, and moisture/chemical resistance is critical. Cable can be installed in free air, in raceways or direct burial.The cable is also approved for wet or dry locations as well as Class 1 Division II industrial hazardous locations per NEC 501-4(b) for (UL) Type tray cables (TC).

Features:
Temperature rating of 90°C wet or dry. Insulation provides excellent electrical, thermal, and physical properties, excellent flame resistance and resistant to crush, compression, cuts and heat deformation. Also conductor insulation provides good low temperature (-25°C) cold bend characteristics.

Compliances:
- Insulated Conductor: XHHW-2, VW-1
- Cable: Direct Burial, sunlight resistant, ER rated
- UL Type TC, 90°C Wet or Dry, 600V
- Passes UL 1277 Flame Test (70,000 BTU/hr)
- Passes IEEE 383 Flame Test (70,000 BTU/hr)
- ICEA S-66-524, 90°C Wet or Dry, 600V & 1000V
- Passes IEEE 1202 Flame Test (70,000 BTU/hr)
- Passes ICEA T-29-520 Flame Test (210,000 BTU/hr)

Conductor:
Fully annealed stranded bare copper to ASTM B3
Class B stranding per ASTM B8

Insulation:
Extruded flame-retardant cross-linked polyolefin (XLP).

Jacket:
Flame-retardant, sunlight resistant, ER rated, Polyvinyl Chloride (PVC)

Cable Construction:
Conductors cabled together with fillers as needed to form a round core. A binder tape is applied over the core.

 

Specifications*:

Size: 10 AWG
Number of Conductors: 12
Minimum AVG Insulation Thickness: 0.030 inches
Minimum AVG Jacket Thickness: 0.060 inches
Outside Diameter: 0.83 inches
Net Weight: 0.600 lbs per ft

*Data provided on this page is subject to change based on different manufacturers variances.

More Information
Wire Size10 AWG
# of Conductors12 Conductors
O.D. (Inches)0.83